Indoor metal enclosed switchgear
Flexible design: fully assembled, expandable, with various installation methods, maintenance-free.
High safety: meets the requirements of 5 prevention, double protection + visual operation and maintenance.
Easy to operate: manual/electric dual mode, remote control supported, stable mechanism.
Strong adaptability: Uniform installation dimensions, no modification required, compatible with various cabinet layouts.
Efficient operation maintenance: Forward maintenance, visual observation window reduces inspection and maintenance costs.
Wide application: Wall-mounted units are available, suitable for indoor and outdoor power distribution.
HXGN-12 AC metal distribution board (ring main unit)
I. Product Overview
HXGN-12 AC with metal enclosed distribution equipment (called ring main unit, RMU) is a new type of high voltage distribution system designed for urban electrical repair and construction applications. It is suitable for interrupting load current, short circuit current and creating short circuit current in power systems.
The distribution equipment is equipped with a vacuum load switch and a spring mechanism supporting both manual and electrical operation modes. The earthing switch and disconnector have manual controls. Featuring complete components, compact dimensions, no risk of fire or explosion, and reliable "five-prevention" functions, it adapts to the safe operation requirements of various power distribution scenarios.
II. Detailed technical parameters
No. |
Item |
Subdivision |
FN12-10 |
FN25-12 |
1 |
Rated voltage |
kv |
12 |
12 |
2 |
1 minute withstand voltage at power frequency |
kv |
42 kV to ground and phase to phase; 48 kV insulating break |
42 kV to ground and phase to phase; 48 kV insulating break |
3 |
Lightning impulse withstand voltage (peak value) |
kv |
75 kV to ground and phase to phase; 85 kV insulation break |
75 kV to ground and phase to phase; 85 kV insulation break |
4 |
Rated frequency |
Idk |
50 |
50 |
5 |
Rated current of main busbar |
A |
630 |
630 |
6 |
Rated current |
A |
630 |
630 |
7 |
Electrical life at rated current |
Time |
Not less than 1000 |
At least 100 |
8 |
Bandwidthno-load transformer |
kVA |
1250 |
1250 |
9 |
Rated thermal stability current |
kA/s |
20/4; Grounding switch 20/2 |
20/4; Grounding switch 20/2 |
10 |
Nominal dynamic stable current (peak value) |
ka |
50 |
50 |
11 |
Rated short-circuit current (peak value) |
ka |
50 |
50 |
12 |
Rated current of the fuse |
A |
100 |
100 |
13 |
Nominal transmission current |
A |
1500 |
2000 |
14 |
Rated short-circuit breaking current |
ka |
31.5 |
31.5 |
15 |
The type of the corresponding fuse |
/ |
S□LAJ-12 (XRNT□-10) |
S□LAJ-12 (XRNT□-10) |
16 |
Mechanical life |
Time |
2000 |
10000 |
17 |
1 minute auxiliary circuit voltage by power frequency |
kv |
2 |
2 |
18 |
Working voltage of the electrical mechanism |
IN |
AC/DC 220V, 110V |
AC/DC 220V, 110V |
19 |
Protection class |
/ |
IP2X |
IP2X |
20 |
Outline measurement (W×D×H) |
mm |
650(850)×900×2000(2200) |
650(850)×900×2000(2200) |
III.. Ordering Instructions
When placing an order, the user provides the following materials:
Main circuit wiring diagram
Drawing of the distribution equipment installation diagram
Auxiliary circuit diagram and circuit diagram in distribution equipment (if necessary)
Written materials for other special requirements
IV.. Application Scenarios
Upgrading the city's power grid and new power distribution projects
Electrical distribution rooms in residential and commercial complexes
Box-type power distribution systems for industrial plants and outdoor substations
Grid-connected power distribution systems for new energy generation