Switching equipment in a metal enclosure

KYN28A-12 Switching Equipment – ​​Key Benefits

1.Safe and reliable: Full armored compartment design + full 5-lock anti-malfunction mechanism.

2.High protection: IP4X housing, IP2X with door open, dust and moisture resistant.

3.Easy maintenance: central retractable automatic trolley, quick replacement.

4.Flexible application: Modular design for single/section/dual busbar systems.

5.Powerful short-circuit capacity: up to 50kA breaking capacity, stable under fault conditions.

6.Compact design: space saving, suitable for indoor distribution rooms.


Product Details

KYN28A-12 Armored Central AC Switchgear with Metal Enclosed Switchgear

1. Product Description

The KYN28A-12 armored central metal switchgear (hereinafter referred to as the switchgear) is a new product independently developed by our company through the absorption of advanced manufacturing technologies from both domestic and international sources. It can replace various legacy metal switchgear and is suitable for three-phase AC 50Hz, 3.6-12 kV networks. It is used for receiving and distributing electrical power, as well as for circuit control, monitoring, and protection. It can be used with single busbar, sectional single busbar, or dual busbar systems.

The switchgear complies with standards including IEC298 Metallic Switchgear and Controlgear for Rated Voltages Above 1 kV and Including 12 kV, IEC694 Common Clauses for High-Voltage Switchgear and Controlgear, China's GB3906 AC Metal-Enclosed Switchgear for Rated Voltages from 3.6 kV to 40.5 kV, DL404 Ordering Specifications for Indoor AC High-Voltage Switchgear, and Germany's DIN VDE0670 AC Standard for Rated Voltages Above 1 kV. It is also equipped with ideal and reliable fault-control functions.


Switching equipment in a metal enclosure

2. Product model and implication

Model format: K Y N 28 A - 12 / □□□ - □


Letter/Number

Additional Code (right)

Consequences

TO

Armored metal switchgear

Nominal voltage (kV)

Rated voltage

AND

Type that can be decommissioned

Main circuit number

Number of primary wiring diagrams

N

Conditions of use (indoors)

Working mechanism characteristics code

D: Electromagnetic; T: Spring

28

Design serial number

Rated current (A)

Rated current of distribution equipment

A

Improved type

Rated short-circuit breaking current (kA)

Short-circuit breaking capacity

3. Terms of Service

  1. Ambient temperature: upper limit +40°C, lower limit -10°C

  2. Height: no more than 1000 m

  3. Relative humidity: average daily relative humidity ≤95%, monthly average relative humidity ≤90%

  4. Seismic intensity: no more than 8 degrees

  5. The installation site is free from fire, explosion hazard, heavy pollution, chemical corrosion and strong vibration.

  6. If the terms of service exceed the above scope, the user must negotiate with our company to determine the permissible scope and technical measures.

4. Ordering instructions

  1. The supply area of ​​10 kV pull-out distribution equipment is determined according to the configuration diagram provided by the purchaser.

  2. All distribution devices are equipped with relays, meters and secondary control devices in accordance with the secondary wiring drawings provided by the design institute.

  3. The distribution equipment includes terminals, switches and circuit breakers connected externally, and the secondary wiring inside the cabinet is completely connected according to the secondary wiring diagram.

5. Technical parameters

Item

Subdivision

Data





Rated voltage

kv

3, 6, 7.2, 12


Rated frequency

Idk

50


Rated current of the circuit breaker

A

630, 1250, 1600, 2000, 2500, 3150


Rated Current of the Distribution Cabinet

A

630, 1250, 1600, 2000, 2500, 3150


Rated dynamic stability current (4S)

ka

16, 20, 25, 31.5, 40, 50


Rated stable current (peak value)

ka

40, 50, 63, 80, 100, 125


Rated short-circuit breaking current

ka

16, 20, 25, 31.5, 40, 50


Rated short-circuit current (peak value)

ka

40, 50, 63, 80, 100, 125


Nominal insulation level

The voltage can withstand the power frequency for 1 minute

kv

24, 32, 42


Lightning surge withstand voltage

kv

40, 60, 75

Degree of protection

-

IP4X - for the enclosure, IP2X - when the isolated compartment and the circuit breaker door are opened